(1) New 8'x10'x8'H cam-locking walk-in cooler panel kit 

(1) New Pre-hung standard man entry door 

(1) New 1 HP medium-temperature outdoor condenser, with cover

(1) New 9,000BTU medium-temperature evaporator

(1) Medium-temperature installation kit 

 

All of our walk-in coolers and freezers come with very simple instructions, ready to be installed. We can provide options for your walk-in as well. If you are building on a material other than concrete, we can offer you an insuled floor. If you happen to be building your cooler outdoors, we can offer you a rubber membrane roof to help your unit withstand the elements. We also back all of our materials with warranties. 

 

Warranties:

5 years on panels

3 years on doors

1 year on refrigeration parts 

 

All Pro Coolers strives to provide quailty materials at a price the consumer can afford. 

New 8'x10'x8'H Walk-In Cooler Kit

$8,660.00Price
  • 1 HP medium-temperature outdoor condenser, with cover: 

    Electrical :

    208-230 V/60 Hz. 1 Phase Nominal Performance Capacity 2,085 / 4,031 Watts 7,114 / 13,754 BTU/Hr 1,793 / 3,466 Kcal/Hr Power Input 1,450 / 1,887 Watts Locked Rotor Amps 43.00 / 43.00 Amps Max Continuous Current - / - Amps Rated Load Amps 6.40 / 8.30 Amps COP 1.44 / 2.14 Watts / Watts EER 4.91 / 7.29 BTU/W-Hr

    Testing Conditions:

    Condensing Temperature 120.00 °C 248.0 °F Evaporating Temperature 20.00 / - °C 68.0 / - °F Liquid Temperature 120.00 °C 248.0 °F Return Gas Temperature 39.00 °C 102.2 °F Ambient Temperature 95.00 °C 203.0 °F

    Application:

    Evaporating Temp. Range MBP/HBP @ -9.40 ° C to 55.00 ° C (15.1° F to 131.0° F) Heat Pump - ° C to - ° C (-° F to -° F) Refrigerant R404A Refrigerant Flow Control Capillary tube/Expansion valve

    Compressor:

    Cooling Fan Compressor and Motor data Compressor Type Reciprocating Displacement 24.20 cc. Oil Type Polyolester Oil Oil Charge 850 cc. Motor Type C.S.R. ; 2 Pole 3,500 / 3,500 r/m Voltage Range 198-264/- Volts 60/- Hz. Winding Resistance at 25 ° C Start 5.90 Ohms Run 1.70 Ohms Weight with Oil 22.11 Kg. Weight with Oil and Accessories 22.86 Kg.

    Electrical Components:

    Motor Protector Type Internal Overload Model Number KGE 656-1 Open / Close 140-150 / 70-52 ° C 1st Cycle trip at 25 ° C 25.00 Amps(main) 45.00 Amps(start) Motor Starter Type Potential Relay

    Model Number:

    KGE 680 (GE3ARR3UX3AT2)

    Pick Up (max.) 186.00-215.00 Volts Drop Out (min.) 40.00-90.00 Volts Terminal Cover KGM 901-1 Start Capacitor 88-106 µF 330 VAC. Disch Resistor for Start Cap 15000 Run Capacitor 25 µF 440 VAC.

     

    9,000 BTU medium-temperature evaporator:

    • Specifications

      British thermal unit (Btu/H): 9,000
      Cubic Foot per Minute ( CFM ): 1,400
      Quantity, Fan Motors: 2
      Length ( inches ): 46
      Width ( inches ): 15
      Height ( inches ): 15

      SUCTION TUBE:7/8",CONNECT TO EXPAN.VALVE:1/2"